The short answer
Measure the garment, then bond it to the wearer’s grounding system so it is not an isolated floating conductor.
Three garment classes
- Under 1 × 10^11 ohmsStatic control garmentPoint-to-point surface resistance. Panel-to-panel under that is the static-shielding minimum.
- Under 1 × 10^9 ohmsGroundable garmentPoint-to-point and point-to-groundable point.
- Under 3.5 × 10^7 ohmsGarment systemPoint-to-groundable point while a person wears it and is connected by a wrist strap.
How to classify and ground an ESD smock
Confirm static shielding
The minimum definition is panel-to-panel conductivity under 1 × 10^11 ohms. A Static Control Garment has point-to-point surface resistance under 1 × 10^11 ohms. Lay the garment on an insulative surface and place the meter electrodes on the sleeve panels.
Check a groundable garment
A Groundable Static Control Garment has surface resistance under 1 × 10^9 ohms point-to-point and point-to-groundable point. Replace one sleeve electrode with a ground for the point-to-groundable-point test.
Check the garment system on a person
A Groundable Static Control Garment System measures under 3.5 × 10^7 ohms point-to-groundable point while a person wears it and is connected by the wrist strap. The smock is not the primary ground.
Bond the smock so it cannot float
TR20.20 says that after the panels conduct, the garment should be electrically bonded to the wearer’s grounding system so it does not act as a floating conductor. Wrist straps or footwear and flooring stay the primary ground.
Shop the garment test
ESD Smock testing procedure requires the fabric to be measured as “static dissipative” on the Ohms scale and to be grounded (bonded electrically to a grounding system) so that it is not an isolated floating conductor. In this article, we review how ANSI / ESD S20.20-2021 defines ESD Smocks and explain the “isolated floating conductor” issue with wearing ESD clothing.
Isolated Floating Conductor Auditing
ESD smocks are precisely “groundable” because they are woven with conductive black carbon-based threading.



If an ESD Garment is not electrically bonded to mats, wrist straps, or floors that are grounded, it becomes a floating lightning rod- an “isolated floating conductor” essentially. The floating conductor issue is acknowledged by the ESD Association in TR20.20-20 section 5.3.13 ‘Garments’:
“After verifying that the garment has electrical conductivity through all panels, the garment should be electrically bonded to the grounding system of the wearer so as not to act as a floating conductor.”
As stated in the document:
“The single most important concept in the field of static control is grounding. Attaching all electrically conductive and dissipative items in the workplace to ground allows built-up electrostatic charges to equalize with ground potential. A grounded conductor cannot hold a static charge.”
A critical S20.20 principle:
Smocks are not primary personnel grounding devices
So:
- Wrist straps (or footwear/flooring) are always primary
- Smocks may:
- equalize potential
- shield fields
- reduce charge generation
- optionally provide a parallel ground path
TR53 reflects this by not requiring garments alone to meet personnel grounding limits.
Questions this guide answers
What are the three garment types in S20.20?
Static Control Garments, Groundable Static Control Garments, and Groundable Static Control Garment Systems. STM2.1 covers the resistance tests. TR53 covers grounding, including garments worn with wrist straps.
What resistance is static shielding?
Panel-to-panel conductivity less than 1 × 10^11 ohms. A panel is a sewn section such as a sleeve or the torso.
Why is 1 × 10^9 ohms called out for a groundable garment?
The article says that limit lines up with the S4.1 recommendation for workstation mats and the TR53 recommendation for shoe grounders.
Is the smock the person’s ground?
No. Wrist straps, or footwear and flooring, are the primary personnel ground. A smock may equalize potential, shield fields, reduce charge generation, and optionally add a parallel path.