• 2-layer static dissipative rubber matting for ESD grounding in ANSI / ESD S20.20 compliant work areas for static control.

ANSI / ESD S4.1 and S7.1 compliant for cart, floor, rack, shelf, table, and tray liner uses.

SizesQty 1-9Qty 10+
24" x 50'$443.78 USD$406.80 USD
30" x 50'$554.72 USD$508.49 USD
36" x 50'$665.66 USD$610.19 USD
48" x 50'$887.54 USD$813.57 USD

Prices

SizesQty 1-9Qty 10+
24" x 50'$443.78 USD$406.80 USD
30" x 50'$554.72 USD$508.49 USD
36" x 50'$665.66 USD$610.19 USD
48" x 50'$887.54 USD$813.57 USD




































Specs

► Meets ANSI / ESD STM 4.1 Standard using FTMS 101C Method 4046.

► Lead-Free. Recyclable. Meets European Union (EU) Restriction of Hazardous Substances Directive (RoHS) regulating the reuse of products used in electrical and electronic equipment.

PropertiesUnitsTypical aluesTest Method
Material-Nitrile Butadiene Rubber / Carbon-
ThicknessInches.08ASTM D-2103
ThicknessMillimetres2ASTM D-2103
Tensile Strength • Top Layerkg / sq. cm> 120ASTM D-412
Tensile Strength • Bottom Layerkg / sq. cm> 160ASTM D-412
Tear Strength • Top Layerkg / sq. cm> 90ASTM D-412
Tear Strength • Bottom Layerkg / sq. cm> 100ASTM D-412
Elongation • Top Layer%350ASTM D-412
Elongation • Bottom Layer%250ASTM D-412
Hardness • Top LayerShore A50ASTM D-2240
Hardness • Bottom LayerShore A60ASTM D-2240
Gravity • Top Layer-1.3ASTM D-792
Gravity • Bottom Layer-1.4ASTM D-792
ESD Surface Resistance • Top Layerohms / square< 109ASTM D-257
ESD Surface Resistance • Bottom Layerohms / square< 105ASTM D-257
Volume Resistivity • Top Layerohms / square< 108ASTM D-257
Volume Resistivity • Bottom Layerohms / square< 104ASTM D-257
Static Decayseconds< 0.01EIA-541
Temperature ToleranceFahrenheit / Celsius187F / 86C-

Connect Grounding Cables to Mats

• The grounding cables should be common point grounds to connect wrist straps to your workstation or mat grounds to bond the roll separately onto the floor.

ESD Grounding Method for a Common Point Ground

ESD Grounding Method for a Mat Grounding Cable

The top anti static side of the mat collects static off of hands, feet, tools, and equipment laid on top of it at a static dissipative rate, (1 x 106 to 9 x 108 ohms / square).

The bottom of the mat then conducts static to ground at a conductive rate, (1 x 103 to 9 x 104 ohms / square).

ESD Resistance Chart for an Anti Static Mat

If the mat lies on an insulating surface, such as a wood bench, bond it with snaps and a grounding cable to the workstation common point ground. Connect that common point ground to the equipment grounding conductor. Use that conductor as the ESD ground. Do not use the outlet’s energized contacts as a ground.

ESD Grounding Method for an ESD Workstation

Several grounding cables may meet at the same common point ground. They should not be daisy-chained. Connect each cable directly to the common point ground.

The equipment grounding conductor holds the mat and the other bonded parts of the workstation at the same potential.

ANSI / ESD S4.1 Test Data

Static Dissipative Range for ESD Anti Static Mats

To satisfy the ANSI / ESD S4.1 Worksurfaces – Resistance Measurements test standard the top static dissipative part of the mat was measured using resistance-to-groundable point and resistance point-to-point tests.

ANSI / ESD S4.1 guidelines at section 8.0 recommend resistance-to-groundable point (RTG) tests should find the top surface of grounded mats measure ESD resistance between 1 x 106 and 1 x 109 ohms.

Resistance point-to-point (also known as top-to-top or RTT) tests should measure the ESD resistance of the top surface of the mats at greater than or equal to 1 x 106 ohms.

The linked qualification report covers 12% and 48% relative humidity, with readings under 1.0×109 ohms.

ESD Resistance Chart for Low Relative Humidity Test of 5300 Series Anti Static Mat

In our low relative humidity test, the sample with the least resistance measured 1.2 x 107 ohms.

The mat sample with the highest resistance measured 3.9 x 107 ohms / square.

ESD Resistance Chart for Moderate Relative Humidity Test of 5300 Series Anti Static Mat

In our moderate relative humidity test, the sample with the least resistance measured 1.0 x 107 ohms.

The mat sample with the highest resistance measured 9.8 x 107 ohms.