How to use a Meter to Test ESD Mats

Anti Static Mat Testing

2 min read

Add as Preferred Source
Prioritize this site in Google AI Overviews & Search results
Authored by Doug Wagner | Elimstat.com • Published July 5, 2018 • Updated January 19, 2022

The short answer

ANSI/ESD S4.1 uses resistance, in ohms, for a point-to-point test and a resistance-to-groundable-point test.

S4.1 limits in this article

  1. RTTPoint to pointGreater than or equal to 1 × 10^6 ohms. Two 5 pound electrodes about 10 inches apart.
  2. RTGTo a groundable pointBetween 1 × 10^6 and 1 × 10^9 ohms. One electrode, black lead on a grounded point.

How to test an ESD mat with a resistance meter

  1. Measure resistance, not resistivity

    Resistivity is ohms per square. Resistance is ohms. ESD TR20.20 uses surface resistance for this test. The article calls a material static dissipative above 1 × 10^6 ohms and below 1 × 10^12 ohms.

  2. Run resistance top-to-top

    S4.1 section 8.0 wants point-to-point resistance greater than or equal to 1 × 10^6 ohms. Do not clean the surface. Remove only items that interfere, including ESD-sensitive devices. Place two 5 pound electrodes about 10 inches apart, 2 inches from any edge, and 3 inches from any grounded point, on the most used area. Hold the test button until the reading appears.

  3. Run resistance to a groundable point

    S4.1 section 8.0 wants RTG between 1 × 10^6 and 1 × 10^9 ohms. Clip the black lead to a grounded point, place one 5 pound electrode on the furthest convenient point, and hold the test button until the reading appears.

Shop the meter and the mat

The ANSI / ESD Association standard used in the United States to test that an ESD Mat is “static dissipative” is ANSI / ESD S4.1. “Worksurfaces – Resistance Measurements“.

This requires the use of a Surface Resistivity (ESD) Meter to perform both resistance-top-to-top (RTT) and resistance-to-groundable point (RTG) tests.

• RTT Testing for ESD Resistance per ANSI / ESD S4.1
• RTG Testing for ESD Resistance per ANSI / ESD S4.1

1. Surface Resistivity vs. Surface Resistance

“The degree of protection afforded by a worksurface is strongly related to the time needed to discharge an object…. [R]esistance seems the best single predictor of performance of ESD-protective worksurfaces.” 

– ANSI / ESD S4.1-2006

Resistivity and Resistance are not technically the same thing. Resistivity is measured in ohms / square. Resistance is measured in just ohms.

Theoretically, surface resistivity is ten times greater than resistance. For example, a material that measures 108 ohms in surface resistance should measure 109 ohms / square in surface resistivity.

For testing purposes, per ESD TR20.20, the correct unit of measurement is surface resistance (just ohms).

A material is considered static dissipative if it has a resistance greater than 1 x 106 ohms, and has a resistance less than 1 x 1012 ohms.

2. Measure Resistance Top to Top (Point to Point) (RTT)

ANSI / ESD S4.1 guidelines (section 8.0) state that  point-to-point (RTT) tests should find the mat has greater than or equal to 1 x 106 ohms of surface resistance.

Test Procedure in accordance with ANSI/ESD S4.1 section 6.4 Periodic Worksurface Testing:


• Do not clean surface. Remove from the surface only those items that might interfere with the test.
• ESD Sensitive devices shall also be removed.
• Use two 5 pound electrodes and place them on the most commonly used area of the surface. Ensure that the electrodes are about 10″ apart from each other and 2″ away from any edge and 3″ away from any grounded point.
• Push and hold the Test Button until the surface resistance reading is displayed.
• If the most used area is not obvious, use two points near the center of the surface.

3. Measure Resistance to Groundable Point (RTG)

ANSI / ESD S4.1 guidelines (section 8.0) states that resistance-to-groundable point (RTG) tests should find the mat has between 1 x 106 and 1 x 109 ohms of surface resistance.

Test Procedure in accordance with ANSI/ESD S4.1 section 6.4 Periodic Worksurface Testing:


• Do not clean surface. Remove from the surface only those items that might interfere with the test.
• ESD Sensitive devices shall also be removed.
• Clip the black test lead to a grounded point.
• Use one 5 pound electrode on the other test lead and place the electrode on the furthest convenient point on the surface.
• Push and hold the Test Button until the surface resistance reading is displayed.

Back to Top ▲

Questions this guide answers

Which standard tests a worksurface mat?

ANSI/ESD S4.1, Worksurfaces – Resistance Measurements. It uses a surface resistance meter for RTT and RTG.

What is the difference between resistivity and resistance?

Resistivity is ohms per square. Resistance is ohms. The article says resistivity is theoretically ten times resistance, and that TR20.20 uses resistance for the test.

What should an RTT reading show?

Greater than or equal to 1 × 10^6 ohms, per S4.1 section 8.0.

What should an RTG reading show?

Between 1 × 10^6 and 1 × 10^9 ohms, per S4.1 section 8.0.

How far apart are the RTT electrodes?

About 10 inches apart, 2 inches from any edge, and 3 inches from any grounded point. If the most used area is not obvious, use two points near the center.